703Bolt – Firmware – Troubleshooting - SDI wont work on the 703 Bolt after firmware update
PROBLEM
I updated two 703 Bolt monitors and the SDI-Out will not work. I had to roll back to the older firmware to get the SDI-Out working
The firmware that causes the SDI-Out issue is v3.4.0., I had to roll it back to v3.3.6. The serial numbers for the monitors I updated are: 703SK-00728 and 73BS190510069."
SOLUTION
There is an issue with the firmware: 3.4.0->3.4.4. Downgrade to 3.3.6 or higher than 3.5+
Keywords
broken, sdi, video, downstream, output, out, firmware update, updated